Din-Rail AC Three Phase Multifunction Energy Meter SPM93 for measure kWh 7+1 digits LCD display with Modbus protocol
Main Documents
Compatible Software
Smart PiEMS System
- SPM93 is completely conformed to the relative requirements of the International Standard IDT IEC 62053-21:2003 (Class 1 ), IDT IEC 62053-22:2003(Class 0.5S ). It is an integration of up-to-date micro-electronics technique, special large scale integrate circuit, advanced technique of digital sampling technique and SMT techniques etc.. Combined with RS485 port, Modbus-RTU or DL/T 645-2007 communication protocol, it makes easy to integrate electrical distribution measurements into Smart PiEMS energy management system and Smart PiDMS distribution management system.
- SPM93 three phase energy meter is used for measuring active energy power
consumption in a rated frequency of 50Hz or 60Hz three phase alternating current
circuit. LCD display total kWh (Imp. & Exp.), total kWh (Imp. & Exp.), Multi-tariff
energy, voltage, current, power, power factor, frequency. It is characterized with good
reliability, compact size, light weight, specious nice appearance and easy installation.
Specification
Rated current |
Direct 5(63) Or5(6)A via CT |
Connection mode |
3-phase4-wire | ||
Pulse output |
2channels(Settable for kWh or kvarh) | ||||
Rated voltage |
AC 220V ph-N or 120Vph-N (Optional) |
Starting Current |
0.4%lb(direct connect),0.2%lb(via CT) | ||
Frequency |
50/60Hz(Optional),range:47~65Hz |
Power Frequency withstand voltage |
4kV | ||
Power Loss |
<2W |
Accuracy |
kWh accuracy:class 0.5s or class 1.0 | ||
Power supply |
Self supply (Note:RS485 won't work when conned 1 phase,) For 220VAC(L-N),range:184~276VAC For 120WAC (L-N),range:96~144VAC |
Pulse constant |
200-2000 | ||
Dimension |
72*100*70mm(4 module) | ||||
Communication |
RS485 serial,MODBUS-RTU or DL/T645 Protocol Baud rate:2400,4800,9600,19200 Address:1~247 |
Wire Diameters |
7mmx7mm(16mm²) | ||
Standard (EMC) |
Electrostatic discharge immunity test IEC 61000-4-2,Level 4 Radiated immunity test IEC 61000-4-3,Level 3 Electrical fast transient/burst immunity test IEC 61000-4-4,Level 4 Surge immunity test (1,2/50μs~8/20μs) IEC 61000-4-5,Level 4 Conducted emission EN55022,Class B Radiated emission EN55022,Class B | ||||
Environment |
Operating temperature:-20℃-+55 ℃ Storage temperature:-40℃~+70 ℃ Humidity:5%~95%non-condensing | ||||
Parameter |
Accuracy |
Resolution |
Measuring Range |
||
Voltage |
0.2% |
0.01V |
For 220Vac(L-N),range:184~276Vac For 120Vac (L-N),range:96-144V |
||
Current |
0.2% |
0.001A |
Direct:5(63) Via CT:5(6)A |
||
Active power |
0.5% |
0.1W |
0~1MW |
||
Reactive power |
1.0% |
0.1var |
0~1Mvar |
||
Apparent power |
0.5% |
0.1VA |
0-1MVA |
||
Power factor |
0.5% |
0.001 |
-1.000~+1.000 |
||
Frequency |
0.01 |
0.01Hz |
47-65Hz |
||
Active energy |
Class 1 for 5(63)A |
0.1kWh |
0-9999999.9kWh |
||
Class 0.5s for 5(6)A |
|||||
Reactive energy |
Class 2 |
0.1kvarh |
0-9999999.9kvarh |
video
Incorporate craftsmanship and responsibility into the products, Pilot Technology continues to promote the construction of standardized, automated and informational production lines to realize the digital intelligentize of production.
Learn more from our product video review.