Leave Your Message
AC Panel Mount or DIN Rail Mount Three Phase Multifunction Energy Meter PMAC770 PMAC770-DR Power Quality Analysis suit for LV/HV voltage system

Panel type multifunction power meter

AC Panel Mount or DIN Rail Mount Three Phase Multifunction Energy Meter PMAC770 PMAC770-DR Power Quality Analysis suit for LV/HV voltage system

PMAC770 provides the main functions as below: 

1. Real-time measuring data,true RMS

2. Al energy data (include real energy,multi-tariff energy, history energy, 1"-13*harmonic energy).

3. Power quality analysis

4. Demand calculation

5. Build-in clock and event log

6. Over/under limit alarm

7. Phase sequence checking

8. Modbus-RTU/ BACnet MS/TP / MODBUS TCP/IP communication (Optional)

9. Digital input/Digital output (DI/DO)

10. Analog input Analog output (Al/AO,optional)

11. 2 pulse output (optional) etc.

      Main Documents

      Compatible Software

      PiEMS System1vwd

      Smart PiEMS System

      Product Introduction

      zc8r
      • PMAC770 Three Phase Multifunction Power Meter is designed for monitoring and displaying all kinds of electricity parameters.It's widely used in low voltage and medium voltage distribution/automation system.
      wow3q

        Features

      • 1.Suit for LV/HV voltage system .For low voltage system,direct connect up to 690V(L-L) AC .For high voltage system,support connect up to 65kV

         2.True-RMS measuring parameter .True-RMS measuring parameters includes:U,I,P,Q,S,PF,F,kWh,kvarh,kVAh

         3.Demand calculation .2 kinds of demand modes:fixed block and rolling block
      20160419cslznnjpydoy1n
      • 4.Power quality analysis .31st Harmonic analysis,K factor,unbalance etc.
        5.*TOU (Multi-tariff billing),historical data of 31 days and 12 months .TOU,4 tariffs,8 time period in 24 hours
        6.Max./Min.Record (U,I,P,Q*)
        7.Under/over limit alarm
         8.64M bit Memory,Build-in Web .Real-time data inquiry by Web .Save monitoring data (Time interval settable 1min,5min,10min,15min,30min) .Support FTP for download memory data
      PMAC7702412q
      • 10.Multiple Communication .BACnet MS/TP Protocol(RS485 port) .MODBUS-RTU Protocol(RS485Port) .MODBUS-TCP/IP Protocol (Ethemet part)
        11.DI/DO
        12.High accuracy
        .Active energy:according to IEC62053-22,class0.5s
        .Reactive energy: according to IEC62053-23,class 2

      20160419txrujjekadbt76w

      Specification

      Connection mode 3-phase 3-wire,3-phase 4-wire,1-phase 2-wire Communication Modbus- RTU Protocol RS485 serial Baud rate:2400,4800,9600,19200, 38400bps Address:1~247
      Metering True RMS,1 sec refresh time
      Input Rate current:1Aor 5A Rate voltage: Direct 120V,220V,240V,277V,398Vph-N (optional) PT secondary.1-398V(settable) Frequency:50/60Hz Modbus- TCP/IP Ethernet communication port Support connect 10M/100M Ethernet Modbus TCP/IP,Web,FTP
      BACnet MS/TP protocol RS485serial Baud rate:2400,4800,9600,19200, 38400,57600,76800bps Address:1..127,excluding 99
      Overload 120%of rated,continuously Instantaneous current:10 times/sec Instantaneous voltage:2 times/sec
      Status input Wet contact,extemal power supply   Dimension   LxWx H) PMAC770: Panel:96x96x13.5 mm Cut-out:90x90x58.6 mm(basic) 90x90x80.1 mm(optional module) PMAC770-DR Panel:96x96x12 mm Cut-out:90x90x 58.6 mm(basic)
      Relay output Node capacity.250VAC/5A
      Pulse output Pulse constant:1000~9999 programmable Pulse width:60~100ms programmable Formula;1pulse=(1÷pulse constant × PT× CT) kWh
      Power supply 85~265VAC,85~265VDC(When select P1) 100~420VAC,100~400VDC(When select P2)   Weight Basic unit:approx 550gr. Optional module:50gr.
      Power loss <5VA   Environment Main Module& and other Modules Operating temperature:-10℃~+55 ℃ Storage temperature:-40℃-+70 ℃ Humidity:5%~95%non-condensing
      IP index IP52(front panel)and IP30(case)
      Power frequency withstand voltage AC 2KVIminute BACnet Module Operating temperature:0℃~+50℃ Storage temperature:-5C~+75 ℃ Humidity:10%~95%non-condensing
      Insulation resistance ≥50MΩ
      Impulse withstand voltage 4kV(peak),1.2/50uS

      Standard (EMC)

      Electrostatic discharge immunity test                   IEC 61000-4-2,Level 4
      Radiated immunity test                                           IEC 61000-4-3,Level 3
      Electrical fast transient/burst immunity test       IEC61000-4-4,Level 4

      Surge immunity test(1,2/50μs~8/20μs Conducted emissions Radiated emissions

      IEC 61000-4-5,Level 3

      EN55022,ClassB EN 55022,ClassB

      6579a8fycx6579a8f2el

      video

      Incorporate craftsmanship and responsibility into the products, Pilot Technology continues to promote the construction of standardized, automated and informational production lines to realize the digital intelligentize of production.
      Learn more from our product video review.